The MI-3000 audiometer
The standard MI-3000 audiometer is an economical, manually operated audiometer that tests frequencies from 125 Hz to 8000 Hz, including standard inter-octave frequencies. It is small and light enough to be portable, yet large enough to provide easy access and operation of all audiometer controls.
MI-3000 Plus Version,
in addition to the standard features, the MI-3000 Plus offers flexible communication capabilities via the included Monitor Basics software. This software enables control of the audiometer by a Windows-based computer, allowing the operator to set up, start, and visually track the progress of automatic threshold or screening tests. Completed tests can be printed via the computer’s printer.
Potential users include:
Doctors offices, schools, small industries, hospitals, community health screening organizations
MI-3000 Benefits
Small size and light weight make it easily portable and convenient for small spaces
Economical
Ease of operation simplifies training of operators
Capable of field calibration
About the Standard Version
MI-3000 Audiometer module with prop stand
Complete headset
UL listed low-voltage, double-insulated, detachable power supply
MI-3000 Standard Operator Manual
Telephone support
4-year limited warranty on the MI-3000 audiometer module
Features
Wide range of test frequencies
Quiet push-button operation
Automatic “Up 5, Down 10” output level control
Selectable minimum and maximum output levels
Selectable test frequencies
Built-in “prop stand” tilts the instrument for easier viewing and operation.
Upgradeable to the Plus version
Output levels down to -10 dB HL
About the Plus Version
Testing modes may be switched to manual, single-frequency, or back to automatic testing at any time during a test. Printed tests are easy to read and provide threshold data along with many optional patient demographics.
Plus package includes:
All the accessories supplied with the Standard MI-3000 plus:
Patient response switch
Two (2) patch cords
Computer interface cable
Monitor Basics software package
MI-3000 Plus Operator Manual
Features:
Automatic threshold testing of all or any frequencies from 125 Hz to 8000 Hz
OSHA compliant automatic test and printout
Selectable minimum and maximum output levels
Manual testing through computer or audiometer controls
Single frequency automatic retests
Modified Hughson-Westlake test paradigm
Specifications:
Test Frequencies: 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, and 8000 hz
Frequency Accuracy: Crystal controlled, less than 0.5% error at all frequencies
Intensity Range in dB HL: From -10 to 90 dB 500 Hz through 6000 Hz, -10 to 60 dB @ 125 Hz, and -10 to 85 dB @ 250 and 8000 Hz
Attenuator Linearity: Less than 1 dB error for any 5 dB step, less than 2 dB accumulated error relative to the calibration level
Tone Rise/Fall Times: 35/35 ms typical
Stimulus Characteristics, Pulsed Mode: 200 ms on and 200 ms off (50% duty cycle)
Audiometer Calibration: Meets ANSI S3.6 1996 standard for Audiometers and OSHA 29 CFR 1910.95. Output levels are calibrated through secured keyboard entry.
Safety: Unit is powered by a Safety Extra Low Voltage (SELV) rated input from a UL listed, double-insulated detachable power supply.
Earphone: Telephonics Corporation TDH-49P earphones with MX-41/AR cushions
Power Requirements: 100-240 VAC 50-60 Hz, less than 0.5 A
Physical Dimensions: 8.5” wide, 7” deep, 2” high
Net Weight: Unit, 2 lbs; earphone assembly, 1 lb; power supply, 6 oz.